What Type of Construction Classification Does a Restaurant Fall Under? A Guide for Annapolis Restaurant Owners

Construction type describes what a building is made of and how well it resists fire. Occupancy classification describes what happens inside it. Most restaurants are classified as Group A-2 occupancy. The construction type depends on the building shell you lease or build.

These are two separate ideas, and they’re easy to mix up. Say you open your code report and see “Type III-B” next to “A-2.” Those labels don’t mean the same thing. One is about the building, and one is about your business.

  • Construction type (Types I through V): The materials in the structure and how well they resist fire. Concrete and steel buildings are usually Type I or II. Brick shells with wood floor framing are usually Type III. All-wood buildings are Type V.
  • Occupancy classification (A-2 for most restaurants): What the space is used for and how many people gather there. Assembly spaces, like restaurants, have stricter rules for exits, sprinklers, and restrooms.
  • Mixed occupancy: Two or more uses in one building, like a restaurant with apartments above. The code requires fire-rated walls or floors between them. Fire-rated means built to hold back fire for a set amount of time.

Why does the difference matter to you? Opening a restaurant can change a space’s occupancy classification. It can’t change the construction type of a 90-year-old brick building.

Here’s how that can play out. Say you lease a narrow brick storefront in downtown Annapolis that used to be a clothing shop. The building is Type III-B, with no sprinklers. As a store, it was classified Group M, for mercantile.

Plan a 90-seat restaurant there, and the occupancy changes to A-2. That change can bring new rules for sprinklers, exits, and restroom counts. The building itself stays the same. What changes is which code rules apply to it.

A third term, occupant load, gets mixed into this too. Occupant load is the number of people the code says your space can hold. Your architect figures it from the floor area and how each area is used. It’s the number that decides whether a food space counts as A-2.

Most restaurants become A-2 once the occupant load reaches 50 or more. Under 50, the space is usually classified Group B, for business, with lighter rules. A few extra tables can push the count over that line. That’s why it helps to know the rule before your layout is final.

Your architect handles the code analysis and the permit applications. That includes classifying the construction type and the occupancy. As your restaurant construction contractor, we coordinate the construction schedule around permit approvals and prepare the job for inspections. Knowing these terms won’t get your permit issued, but it will help you ask better questions about your drawings.

What Occupancy Classification Usually Applies to a Restaurant

Most restaurants are classified as Group A-2. The International Building Code (IBC) uses Group A for places where people gather. A-2 covers restaurants, bars, banquet halls, and nightclubs. Maryland uses the IBC as the base for its state building code, so Annapolis projects follow that framework.

The reasoning is simple. Restaurants put a lot of people in one room with cooking equipment, and sometimes alcohol. That mix raises the fire and safety risk, so the code asks for more.

Not every food business is A-2, though. When a space holds fewer than 50 people, it’s usually classified Group B instead. That’s why a small coffee shop or grab-and-go counter often isn’t treated as an assembly space. Some owners assume every food business is A-2, then learn their small cafe has lighter rules.

Here’s how the classification usually gets settled on a project:

  • Your architect measures the floor area of each part of the space.
  • Each area gets an occupant load factor, which is the square feet the code assigns per person.
  • Dining, bar, kitchen, and storage areas use different factors, since the code expects different crowd levels.
  • Those numbers add up to a total occupant load.
  • At 50 or more, the space is usually classified A-2.
  • Under 50, it usually falls under Group B, though the local building official may weigh in.
  • The classification then drives exits, restroom counts, sprinklers, and accessibility details.

That last step is the one that affects your budget and schedule. Going from 48 to 52 occupants can change a lot of the drawings.

Once a space becomes A-2, a few requirements often change:

  • Two exits instead of one, usually with panic hardware. Panic hardware is a push bar that opens the door with one push.
  • Fire sprinklers, once the space passes certain size or occupant load limits.
  • More toilets and sinks, since restroom counts rise with occupant load.
  • Stricter fire ratings for wall and ceiling finishes along exit paths.
  • A posted sign showing the room’s maximum occupant load.

Here’s a situation to plan for. A tenant asks for eight extra seats late in design. That small change can push the occupant load past 50 and require a second exit. At that point, the owner has to choose between the new seats and the added cost.

Mixed-use buildings add another layer, and downtown Annapolis has many of them. When a restaurant shares a building with other tenants, the code may require fire-rated separation between the uses. Your architect works that out in the drawings. We can help during pre-construction by pricing those details early, before work starts.

The Five Construction Types and What They Mean for a Restaurant Building

The building code sorts every building into one of five construction types. The types are about materials and fire resistance, not about what happens inside. A pizza shop and a bank can share the same Type II building. Here’s a short look at each type.

  • Type I: Noncombustible materials, like concrete and protected steel, with the highest fire ratings. Noncombustible means the material won’t burn. Think high-rises and large mixed-use buildings.
  • Type II: Also noncombustible, but with less fire protection on the structure. It’s common for strip centers and one-story retail buildings.
  • Type III: Noncombustible outside walls, usually brick or block, with wood framing inside. Many older main-street buildings are Type III.
  • Type IV: Heavy timber. These are large wood beams and posts that char slowly in a fire instead of failing fast. You’ll find it in converted mills and warehouses.
  • Type V: Wood framing throughout, inside and out. It’s common in smaller freestanding buildings and older houses converted to businesses.

Types I, II, III, and V each split into A and B, and Type IV has its own subtypes. In the A version, the structure has extra fire protection, and in the B version it has less. That one letter affects how tall and how large the building can be. It also affects how much fire-rated work the build needs.

So what does this mean when you open a restaurant? Types I and II usually allow larger dining rooms, more stories, and more total floor area. A Type V wood building hits its size limits sooner. For a large dining room, the construction type can shape the plan as much as the layout does.

Sprinklers change the math too. A building with sprinklers can usually be taller and larger than the same building without them. That’s why many restaurant deals depend on whether the building already has a sprinkler system.

Downtown Annapolis has many brick-and-wood buildings classified as Type III. They can make great restaurant spaces. But the wood framing inside can mean more fire-rated wall work and more sealing around pipes and ducts. A newer Type II building often needs less of that work.

Take the kitchen exhaust. The grease duct carries greasy air from the hood over your cooking line out through the roof. Where it passes through floors and ceilings, it usually needs a fire-rated enclosure. Wood framing tends to make that enclosure work more involved, while concrete makes cutting through slabs harder.

None of this makes an old building a bad deal. It just means construction type belongs in your budget talks early, before you sign the lease. Your architect confirms the classification on the code sheet, the page in the drawings that lists these code details. We use that sheet to price the build. Understanding how much it costs to build a restaurant building can help you put those requirements into perspective as you evaluate a potential location.

Why Restaurant Owners Work With Encore

Encore Construction is based near Annapolis, and commercial construction is our focus. We build restaurants, retail stores, offices, and medical spaces, not federal contracts or biotech labs. We work across the DC metro, Maryland’s I-95 corridor, and Northern Virginia out to Fredericksburg.

We’re built for repeat work, not one-and-done jobs. That’s how we’ve completed 20+ restaurant projects for the same brand. We manage $15M+ in construction each year, and we still work like a close-knit team.

You’ll always know who to call. Our leadership team stays personally involved, and Joe really does pick up the phone. From pre-construction planning through final inspections, you get clear, steady updates.

Talk Through Your Space Before You Sign

Looking at a restaurant space in Annapolis or nearby? Call Encore or get in touch through our contact form before you sign the lease. We’ll look at the space with you and point out what could affect your budget and schedule. Your architect handles the code analysis, and we’ll show you what it means for the build.

Frequently Asked Questions

What’s the difference between construction type and occupancy classification?

Construction type describes what your building is made of, like brick, wood, or steel. Occupancy classification describes how the space is used, like serving food to 60 people. Opening a restaurant can change a space’s occupancy classification. It can’t change the building’s construction type.

How many seats before a restaurant needs A-2 occupancy classification?

It’s based on occupant load, not seats alone. Your architect figures occupant load from the floor area of the dining room, bar, kitchen, and storage. At 50 or more, most restaurants are classified A-2. Under 50, a small cafe or coffee shop is usually Group B, with lighter rules.

Does an old brick building in Annapolis limit what kind of restaurant I can open?

It can. Many older downtown Annapolis buildings are Type III, which limits building size and adds fire-rated work. Opening a restaurant can also trigger new sprinkler, exit, or restroom rules. Knowing this helps you weigh a lease before you sign it.

Can I assume my space is fine for a restaurant just because it used to be retail?

No. Retail is usually Group M, while a restaurant with an occupant load of 50 or more is Group A-2. That change can require sprinklers, a second exit, and more restrooms the old tenant never needed. Have your architect review the layout against the code before you commit to the space.

Does Maryland’s building code treat restaurants differently than other states?

Not much. Maryland uses the International Building Code as its base, and local jurisdictions can adopt changes. Local building officials also weigh in on close occupant load calls and mixed-use buildings. Your architect will know which code version and local changes apply to your project.

What happens if my restaurant shares a building with apartments or offices?

Your restaurant becomes a separate occupancy from the apartments or offices. The code requires fire-rated walls or floors between them. Your architect designs those separations and handles the code analysis. We plan the construction schedule around that work and prepare it for inspection.